SimPlate® for HPC

Good News for Pour Plate Users—A Method That's Easier to Read and Easier to Use

SimPlate® for HPC is U.S. EPA-approved.

Internal comparisons of SimPlate® for HPC and Standard Methods (9215B) pour plate method show a correlation coefficient (r) of 0.97.

 

  • SimPlate for HPC Product Specifications
    ( sample size, shelf life, uses, and packaging)
  • Patent Information
 

SimPlate® for HPC is easy to use, rapid and accurate

 

Easy
  • No agar preparation.
  • Easy to read.
  • 738/plate Most Probable Number (MPN) counting range minimizes need for dilutions.

 

Rapid
  • Instant media preparation.
  • Less than 2 minutes hands-on time.
  • Reduced read time.

 

Accurate
  • Correlates with US EPA-approved pour plate method 1 using plate count agar and 48-hour, 35°C incubation.2
  • Simplified procedure minimizes chance of contamination.
  • Less subjective interpretation than pour plate.

 

Economical
  • Less equipment to purchase and maintain.
  • Increased productivity saves labor costs.
  • Minimal Quality Control (QC).

 

American Public Health Association Standard Methods for Examination of Water and Wastewater, 19th Ed. 1995, A.D. Eaton, L.S. Clesceri, A.E. Greenberg (eds.), American Public Health Association, Washington, DC.
Data on file at IDEXX Laboratories, Inc.

 

 

SimPlate® for HPC
Representing 150 bacteria 
(under UV light)

 

Pour Plate 
Representing 150 bacteria

Scientific Basis: How SimPlate® for HPC Works

Multiple Enzyme Technology Medium—The SimPlate for HPC medium uses IDEXX's Multiple Enzyme Technology™ (MET™) to detect heterotrophic plate count (HPC) bacteria in water. The reagent contains multiple unique enzyme-substrates, each targeting a different bacterial enzyme. The most common enzymes of waterborne bacteria are all targeted.

 

All of the enzyme-substrates produce the same signal when metabolized. Therefore, a given waterborne bacteria will be able to metabolize one or more enzyme-substrate and produce a signal. In the case of SimPlate for HPC, the signal is fluorescence under 365 nm UV light.

 

After the sample and medium are added to the plate, the wells fill automatically as the user swirls the plate. No pipetting is needed.

 

Once the wells are filled, the plate is angled and excess sample/medium mixture is poured into the absorbent pad. The SimPlate takes advantage of surface tension to hold the proper amount of sample/medium mixture in each of its 84 wells as excess is poured off.

 

SimPlates are incubated upside down to prevent condensation from collecting on the lid. Since each well is isolated from the others, bacteria from one well will cause only that one well to fluoresce.

 

The number of wells that fluoresce is converted to a Most Probable Number (MPN) using the table provided with the product. The high number of wells (84) results in a very high counting range and precise 95% confidence limits. The counting range is from <1 to 738 per plate (more than double a standard pour plate) with the Multi-dose SimPlate for HPC.


SimPlate for HPC Accessories

How to Use SimPlate® for HPC

 
Step 1. 
Add 100 mL sterile diluent to media vessel.
Step 2.
Add 1 mL sample to SimPlate.
Step 3.
Add 9 mL media to SimPlate.
Step 4.
Swirl SimPlate and pour off excess.
Step 5.
Invert and incubate for 48 hours. 
Step 6. 
Read results under UV light. 
SIMPLATE® is the registered trademark of BioControl Systems, Inc. and is used by IDEXX under license from BioControl. Covered by U.S. Patent No. 5,700,655. Other patents pending.

SimPlate for HPC Questions and Answers

 

Is SimPlate for HPC approved by the U.S. EPA?

Yes. SimPlate® for HPC is U.S. Environmental Protection Agency (EPA)-approved for compliance monitoring of drinking water, effective November 29, 2002.

 

What is the U.S. EPA threshold for HPC in drinking water?

As per the 40CFR Part 141.72, surface water systems must provide disinfection at the point of entry whether the water is filtered or not. The distribution system water must have a detectable level of disinfectant or an HPC level under 500/mL.

 

What is the shelf life of SimPlate for HPC?

The shelf life is up to 15 months from date of manufacture.

 

Are SimPlates sterile?

Yes, the base and lid are gamma irradiated. There are 25 plates per plastic sleeve. Any unused plates should remain in the bag and the bag should be closed. Do not leave any unused plates exposed to the environment.

 

Are SimPlates made of recyclable plastic?

The bottom portion of the plate is made of polystyrene #6 and is recyclable. The cover/lid is made of polyvinyl chloride and is not recyclable.

 
Resource List

How to Use SimPlate for HPC (Multi-dose) Video

Resource Library for SimPlate® for HPC

General •  Procedure •  Technical •  Approvals •  MSDS
International documents:  Deutsch •  Español •  Français •  Italiano 

Document TitleDocument TopicPDF Size

General
Water Products CatalogProduct Information2.2 MB
IDEXX Bottled Water BrochureProduct Information 620 KB
SimPlate BrochureProduct Information 240 KB
back to the top
 
 
Procedure
SimPlate for HPC Multi-Dose ProcedureProcedure 1.12 MB
SimPlate for HPC Multi-Dose Procedure (Media Only)Procedure 1.04 MB
SimPlate for HPC Unit-Dose ProcedureProcedure 1.24 MB
 
 
Technical
MPN Tables for SimPlate for HPC Unit- and Multi-doseMPN Tables 22 KB
SimPlate for HPC Paper WQTC 11/1998 (Smith & Townsend)Accuracy  252 KB
SimPlate for HPC Multi-Region Eval. AEM 1/2000 (Jackson et al.)Accuracy  9 KB
SimPlate for HPC Field Study 10/1998 (Stillings et al.)Accuracy  9 KB
 
 
Approvals
Standard Methods Approval of SimPlate for HPC Testing 2005Approval 20 KB
U.S. EPA Approval for SimPlate for HPC 10/2002Approval 62 KB
Quanti-Disc and SimPlate for HPC’s Approval for Use in the UkraineApproval 34.3 KB
South African Approval of SimPlate and Quanti-Disc for HPC Testing of WaterApproval 223 KB
 
 
MSDS
SimPlate for HPC Material Safety Data SheetMaterial Safety Data Sheet 34 KB
Vessel Material Safety Data SheetMaterial Safety Data Sheet 23 KB
 
 
Dokumente Auf Deutsch
IDEXX Bottled Water BroschüreProduktinformation (Deutsch) 569 KB
SimPlate Methode für HPC-Mehrfachdosis (Nur Medium)Verfahren (Deutsch) 1.04 MB
SimPlate MSDSMaterial Safety Data Sheet (Deutsch) 25 KB
 
 
Documentos en Español
IDEXX Folleto de agua embotelladaInformación de producto (Español) 593 KB
Método SimPlate para Dosis Múltiples de RPH (Recuento en Placa de Heterotrofos) - Sólo medioProcedimiento (Español) 1.04 MB
Hoja de datos de seguridad para SimPlateMaterial Safety Data Sheet (Español) 25 KB
 
 
Documents en Français
Brochure IDEXX l'eau embouteilléeInformation sur le produit (Français) 600 KB
Méthode SimPlate pour NBH (Numération des Bactéries Hétérotrophes)Procédure (Français) 1.04 MB
Fiche de sécurité pour SimPlateMaterial Safety Data Sheet (Français) 27 KB
 
 
Documenti in Italiano
IDEXX Brochure Acqua in bottigliaInformazioni di prodotto (Italiano) 588 KB
Metodo SimPlate per Dosaggio Multiplo delle Conte in Piastra di Batteri Eterotrofi (HPC) (Esclusivamente Terreno)Procedura (Italiano) 1.04 MB
SimPlate MSDSMaterial Safety Data Sheet (Italiano) 25 KB
 
Documentos em Português
IDEXX Brochura água engarrafadaInformações sobre o produto (Português) 624 KB
SimPlate MSDSMaterial Safety Data Sheet (Português) 25 KB
 
Documenten in het Nederlands
SimPlate MSDSMaterial Safety Data Sheet (Nederlands) 25 KB
 
Dokumenter på dansk
SimPlate MSDSMaterial Safety Data Sheet (Danske) 25 KB